Application
CHM and CHL pumps are mainly used in industry:
- Air conditioning system
- Cooling system
- Industrial cleaning
- Water treatment (water purification)
- Aquaculture
- Fertilization/metering system
- Environmental applications
Precautions:
- Thin, clean, non-flammable and explosive liquid withoutsolid particles or fibers.
- The pump can transport mineral water, demineralizedwater, pure water, clean oil and other light chemical media.
- When the density or viscosity of the conveyed liquid isgreater than that of water, a high-power motor must beused if necessary.
- Whether the pump is suitable for a specific liquidisdetermined by many factors, the most important of which are the chlorine content, PH value, temperature and the content of solvent and oil.
Model Meaning

Motor
- The motor is fully enclosed, air-cooledtwo-pole motor.
- Protection grade: IP55
- Insulation class: F
- Standard voltage: 50Hz: 1 x220-240V3 x 220- 240V/380-41 5V
- The maximum power of single-phasemotoris 2.2kW.
Operating conditions :
Liquid temperature:
Normal temperature type-15℃to 70
Hot water type 70℃to 110℃
Maximum ambient temperature: 40℃
Maximum operating pressure: 10 bar
The maximum inlet pressure is limited by the maximum operating pressure